ECUsim™ 2000 User Guide
messages have either 11-bit or 29-bit headers. So a typical 11-bit exchange
would appear as follows:
Rx: 7DF 01 00
Tx: 7E8 41 00 BE 1B 30 13
Tx: 7E9 41 00 88 18 00 10
Tx: 7EA 41 00 00 08 00 10
Same exchange on 29-bit CAN:
Rx: 18DB33F1 01 00
Tx: 18DAF110 41 00 BE 1B 30 13
Tx: 18DAF118 41 00 88 18 00 10
Tx: 18DAF128 41 00 00 08 00 10
Monitoring can be turned off using the MON 0 command to increase the
refresh rate. To enable monitoring again, issue MON 1.
6.5 Status Messages
<UART TX OVERFLOW>
UART transmit buffer overflow detected.
<MALFUNCTION EVENT>
User pressed the Fault button.
<WAITING FOR 5 BAUD INIT>
The simulator is waiting for an ISO 9141-2 or ISO 14230-4 5 baud initialization
sequence.
<WAITING FOR FAST INIT>
The simulator is waiting for an ISO 14230-4 fast initialization sequence.
<5 BAUD INIT: OK>
Detected a successful 5 baud initialization sequence.
<FAST INIT: OK>
Detected a successful ISO 14230-4 fast initialization sequence.
<ALL ECUS TIMED OUT>
All virtual ECUs had timed out, because a supported request had not been
received within P3
MAX
(ISO 9141-2 and ISO 14230-4 protocols).