SeaLand VacuFlush 3400 Series Toilets User Manual

Page 13

Advertising
background image

3

TRoubLeSHooTING (cont’d)

SYmpTom 3. Flush valve will not close.

Condition/Procedure
Mode Switch is in SERVICE

position:
Foreign object prevents the flush

valve from closing and the safety

circuit locked flush valve in open

position:
Check for error code at “DO NOT

FLUSH” status light.
Check the voltage output to

the flush valve motor at jack 6,

pins 9 and 0 on the control

module as follows:

Corrective Action
• Return switch to the “Normal” position.

• Reset the control circuit by putting the Mode Switch in the SERVICE

position temporarily, then returning to the NORMAL position. If the

flush valve

did not close, go to next step.

• If showing error, follow the instructions in the Error Code Corrective

Procedures section.

• Pull the control module out as far as the control cables will allow.

Locate jack 6 at the bottom of the control module.

• Remove the green wire from pin 5.
• With DC voltmeter test leads across pins 9 and 10, flip the Mode

Switch between the SERVICE and NORMAL positions. If voltage is

present for about two seconds in the NORMAL position, the flush

valve motor or related wiring is defective.

• If voltage is not present, replace the control module.

SYMPTOM 4. Water will not enter toilet bowl during a flush and when the flush handle is raised

in the “Add Water” position.

Procedure
Place the Water Level switch

in the LOW position. Check

the “WATER VALVE” status

light while pressing the flush

handle down:

Corrective Action
• If the “WATER VALVE” status light comes on, the water valve filter

screen may be plugged with debris, or the water valve or its related

wiring is defective.

• If the “WATER VALVE” status light remains off, replace the control

module.

• If voltage is not present, replace the control module.

SYMPTOM 5. Water will not enter toilet bowl when the flush handle is raised in the “Add Water”

position.

Procedure
Flush the toilet, then place

the Water Level switch in the

LOW position. Then check

the “LO LEVEL” status light

while raising the flush handle:

Corrective Action
• If the “LO LEVEL” status light comes

on, replace the control module.

• If the “LO LEVEL” status light does

not come on, the flush switch or

its related wiring is defective.

SYmpTom 6. Water Level switch has no effect on water level in the “Low” or High” position.

Corrective Action
• Replace control module.

SYmpTom 7. Flush valve will not open when mode Switch is in the “Service” position but opens

during a normal flush cycle.

Corrective Action
• Replace control module.

Advertising