3 recommended spare parts, 4 during extended periods of non-use – SeaLand 5149 VacuFlush toilet User Manual

Page 9

Advertising
background image

9

VacuFlush Pedal-Flush Toilet

Maintenance/Winterizing/Service

Maintenance procedure

Service interval

Notes

ROUTINE

Check all clamped hose joints

below water line for leaks .

Monthly

Check filter screen in water valve .

After first year of service, then as

needed if water flow is noticeably

slower .

Screen is located inside water

valve inlet .

Replace vent filter (if installed in

holding tank vent line) .

Annually

MAJOR SYSTEM MAINTENANCE

Replace duckbill valves in vacuum

generator or vacuum pump .

Every three years

See vacuum generator or

vacuum pump parts list for

replacement kit part number .

Replace flush ball seal and flush

ball (if required).

Every three years

See toilet parts list for replace-

ment kit part number .


7.3

Recommended spare parts

When operating boat or other vehicle in remote areas, keep the following spare parts on hand to
assure continuous toilet system operation .

Description

Where used

Flush ball seal

VacuFlush toilet. See parts list.

Flush ball

VacuFlush toilet. See parts list.

Water valve (in foot pedal)

VacuFlush toilet. See parts list.

Vacuum switch kit

Vacuum tank or vacuum generator. See parts list.

Duckbill valves

Vacuum tank or vacuum generator. See parts list.

To order spare parts, refer to Customer Service section .

7.4

During extended periods of non-use

Sanitation hoses should be cleared if toilet will not be needed for an extended period of time (more
than two weeks) .
1. Fill toilet bowl with water and add 4 oz. (120 ml) of liquid biodegradable laundry detergent

(should NOT contain bleach) .

2. Flush toilet, holding pedal down for about two minutes. Close flush ball.
3 . Turn off water supply to toilet .
4. Flush the toilet without water, allowing the vacuum pump to shut off after the flush. Repeat three

times . (This procedure will minimize any remaining water in the sanitation hoses .)

5 . Turn off power to the vacuum pump .
6 . Completely pump out holding tank .
If system will be subjected to freezing temperatures, please follow above procedure, then winterize
system as described in this manual .

TURN OFF ELECTRICITY AND WATER TO TOILET SYSTEM IF IDLE FOR LONG TIME
If people will not be using the boat for a long time (vacation, maintenance, off-season, etc .), or in the
event of a long electrical power interruption, electrical power and water supply to the toilet system
should be shut off .