Page 4: 3intended use

Advertising
background image

4

4 Components

(fig .

1

, page 2)

Caution!

Overfilling the holding tank can create serious damage to the sanitation system, such as

rupturing the holding tank and releasing tank contents into the bilge . To prevent this pos-

sibility, Dometic recommends using the “full” tank shut-down relay in the toilet’s electronic

control module . The “full” signal from the holding tank can be generated by an optional

Dometic DTM01C tank monitor or DTM04 four-level tank monitor system .

3

Intended use

The SeaLand MasterFlush toilet provides an electric-flush toilet that macerates waste and pumps
it to a holding tank or other effluent storage/disposal system . Operated by a wall-mounted flush
switch, the toilet allows the user to add water to the bowl (before using or flushing) and to flush the
toilet by pushing a button . The Dometic flush switch panel includes lights to indicate when electric
power to the toilet is activated, and when the holding tank (if applicable) is full .

3.1 Benefits

Convenient electronic flush. Add water or flush with the touch of a button .

Choice of two water consumption settings. “Normal” flush uses 0 .85 gal . (3 .2 liters) per flush and adds
water to bowl after flush; “Dry Bowl” setting uses only 0 .45 gal . (1 .7 liters) per flush and does not add
water to the bowl .

Versatile installation. Powerful macerator pump allows toilet to be located up to 98 ft . (30 m) away and
9 .8 ft . (3 m) below holding tank or other discharge line destination .

“Power on”, “3/4” and “full tank” indicator lights. Dometic flush switch panel indicates when
electrical power to toilet is activated, and when holding tank is 75% and/or 100% full (depending on
holding tank level indication system) .

Automatic “full tank” shut-down. When connected to a holding tank level indication system, the
MasterFlush toilet control module will shut off electrical power to the toilet when the holding tank is full .
This safety features prevents overfilling the holding tank, which may cause damage to the boat .

Ref.

Description

A

Macerator toilet

B

Dometic DFT flush switch

C

Control module

D

4-wire cable to toilet macerator
pump and water valve

E

Cable from Dometic flush switch

F

Cable for other mfr . flush switch and
status panel

Ref.

Description

G

Incoming electrical power wires

H

Power wires to raw water pump (opt .)

I

Wire for “full tank” signal

J

Wire for “3/4 full tank” signal

K

Floor mounting hardware kit

L

Floor mounting template

Refer to complete parts list (packed separately)
for additional information .