iNsTAllATiON – sysTeM DiAgrAMs

Flush Water OptiOns

FRESH WATER SYSTEM – All SeaLand macera-

tor toilets can operate with an onboard pressur-

ized freshwater system with a minimum flow rate

of 2.5 gpm (9.5 lpm) at the toilet. Onboard fresh-

water demand systems include a water pump that

automatically draws water from a water storage

tank when a valve anywhere in the piping system

is opened. SeaLand toilets are equipped with

an electrically operated water valve that opens
during

NORMAL and LOW flushing modes.

SeaLand toilets are equipped with an in-line

check valve or air gap to prevent contamination
of onboard potable supplies. See later sections

for specific information on connecting the water
line to the toilet.

INSTALLATION NOTES

• Use cold water only.

• Water supply line: 1/2” (13mm) ID; toilet inlet

fitting is 1/2” (13mm), 14 TPI.

• Requires 2.8 GPM (10.6 LPM) demand water

pump or greater, depending on line restrictions.

• Include shut-off valve in water line for

maintenance purposes.

Please contact your nearest Dometic Sanitation

sales office or distributor for complete details.

WARNING!
HAZARD OF FLOODING – If toilet

uses raw water for flushing at ANY time, a
raw water pump controlled by an automati-
cally operating demand switch MUST NOT
be installed. If the onboard water valve or
any plumbing connections were to leak, the
automatically operated pump would start and

could flood the boat. Failure to comply with
this warning can cause loss of property and
life. See other WARNINGS (p. 4).

RAW WATER SYSTEM – SeaLand macera-

tor toilets can flush on seawater but require a

separate pump for this purpose. The pump is

activated by the signal from the toilet’s electronic

control module that would operate the integral

water valve in a fresh water system. Since raw

water pumps operate at a higher amperage than

the freshwater water valve, a 12 or 24 volt DC

electrical relay must be inserted into the electrical

cables connected to the pump. A kit is available

to convert the standard freshwater toilet to raw

water. The kit contains the electrical relay, hose

insert adapter and related hardware.

INSTALLATION NOTES

• See Notes from Fresh Water System.

• Seacock must be full-flow, marine-quality valve (not

screw-to-close type).

• Use primary and secondary raw water filters.

• Raw water pump MUST NOT be demand type. Pump

is controlled by signal from Control Module near toilet.

• Position vented loop as shown between discharge

side of water pump and toilet. Must be equipped

with integral check valve that permits air into line to

prevent siphoning.

Advertising