Warmer & Cooler Commands in Manual Changeover

Page 4

If the thermostat is configured for Manual
Heat/Cool changeover:

WARMER button press while in Heat or Off
mode:
When the thermostat receives a Warmer command
(button press) through the remote control and the
heater is not running, the set point will be raised
above the room temperature to start the heater
operation. This occurs even if the thermostat was
Off.
When the thermostat receives a Warmer command
and the heater is running, the set point will be
raised 2 degrees above the present set point.

WARMER button press while in Cool mode:
When the thermostat receives a Warmer command
(button press) through the remote control in Cool
mode, and the air conditioner is running, the set
point will be raised to the present room
temperature, which will turn off the air conditioner.
If the Warmer button is pressed and the air
conditioner is not running, the set point will be
raised 2 degrees.