OPERATIONAL FEATURES

– Adjustable tolerance limits in energy (Ws) (for E models only) and time

(sec) with visual alarms.

– Information displays including: number of assemblies, number of rejects,

and number of cycles.

– Fault displays.

– Keypad security.

STARTING UP THE WELDER

Press the ON/OFF button to turn the welder on. The LCD screen will display

the model number, wattage and frequency information. Then the LCD screen

will show the following “ready” display:

This display shows the last weld information – weld time, energy (on E

models only) and power. (After power down and subsequent power up,

values are cleared to zero.)

TEST FEATURE

After the press is turned on, press and hold the TEST button. While

depressing the TEST button, check the display. Make sure the bar graph

indicator on the display (a series of vertical lines that register to the 0 to

100% load meter scale – see example below) does not exceed 20%.

During the testing process, keep in mind that the ultrasonics are only

activated as long as the TEST button is depressed – once you release the

TEST button, ultrasonics is terminated.

A bar graph indicator reading of above 20%, signals that there may be a

problem with the stack. If this occurs check your assembly and re-test.

00.00 sec
000000 J

00 %Pmax

I N S T R U C T I O N M A N U A L • H A N D H E L D W E L D E R S

21

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

0045 Watts

The TEST and Load

Meter check should

always be done for all

cold start-ups, and for

any start-up after the

system has been idle

for 20 minutes or more.