I N S T R U C T I O N M A N U A L • H A N D H E L D W E L D E R S

23

RELATIONSHIP OF TIME AND ENERGY SETTINGS (ON E

MODELS ONLY)

Parameters can be set in the time and energy menus. The settings in both of

these menus should be taken into account when you are setting up a job

since they do not function independently of each other and a parameter in

one menu can impact the effect of a parameter in another menu.

For example, if you specify a weld time of 2 seconds and an energy setting

of 2,000 joules, the weld cycle will be terminated by whichever of the 2

settings (Weld Time or Energy Setting) is reached first – that is, either when

ultrasonics have been applied for 2 seconds or when energy equivalent to

2,000 joules has been delivered to the parts being assembled. If 2 seconds

is reached before 2,000 joules have been delivered, the weld cycle will

terminate regardless of the amount of energy delivered, and vice versa.

The start-up ready screen which shows the last weld information will show a

flashing “sec” or “J” to indicate which setting was achieved first and thereby

terminated the weld cycle. In the example above, if the weld time of 2

seconds is reached before 2000 joules have been delivered, the ready screen

will display “02.00 sec,” with the “sec” flashing, along with whatever energy

was delivered. The peak power delivered (%Pmax) will be displayed as a

percent of the supply rating.

The ability to specify Time and Energy affords maximum control of the weld

process. However, when entering your specifications in the various menus

described below, keep in mind that the settings from previous use remain in

effect until you make a change and use the Enter key to register a new value.

This means that if you want to achieve a weld time of 2 seconds, for

example, you will need to ensure that other entries in the Energy menu will

allow a 2-second weld before an Energy setting is reached (and ultrasonics

are terminated).