I N S T R U C T I O N M A N U A L • M O D E L F C P O W E R S U P P LY

13

O P E R A T I N G P R O C E D U R E S

FRONT PANEL CONTROLS

Located on the front panel of the power supply are the following controls:

1. Red POWER button which turns the unit on and off.

2. Yellow RESET button which resets the power supply following an overload

condition. If an overload condition exists, the button lights up. In addition,

the RESET button must be depressed after the unit is first turned on

before any operation can proceed.

3. Green TEST button which can be used to test ultrasonic operation

(pressing it only manually activates the ultrasonics).

4. OUTPUT CONTROL DIAL which controls fine adjustment of the ampli-

tude of the system’s high-frequency vibrations over the full operating range.

(Major adjustments of amplitude are made through the use of different

boosters – consult your press manual for further information.)

5. LED LOAD METER which indicates the level of ultrasonics that is being

transmitted to the welding press.

RESET

POWER

TEST

OUTPUT CONTROL

100

90

80

70

60

50

40

30

40

60

80

100

20

0

The RESET button is a

built-in safety feature. When

the power supply is

connected to a press, be

sure the press head

actuation signals are not

activated (or closed). If they

are activated, the press

head will descend

immediately when the

RESET button is

depressed.

Advertising