I N S T R U C T I O N M A N U A L • M O D E L F M P O W E R S U P P LY

7.

REF

key which displays energy in Watt Seconds (Ws) when the constant

energy mode has been selected, and permits adjustment of the set value
in .1 Ws increments. Green LED in the upper left corner indicates
completion of an acceptable process cycle.

8.

+LIM / -LIM

keys which display and establish upper and lower quality

control tolerance limits in time (sec.) when energy mode is selected and in
energy (Ws) when time mode is selected. Red LEDs in upper left corner
indicate when rejects occur because either time or energy is above or
below set limits.

9.

TEST

key which can be used to test ultrasonic operation and displays idle

losses of converter/booster/horn as a percentage of maximum power when
key is depressed.

10.

INFO

key which displays data (or parameters) on the LCD screen. Can be

pressed up to eight times to display the following data (in the order shown):

— Number of cycles

— Number of rejects

— Rated output power of system

— Mode Codes (functions selected)

— Length of Graph Time Axis when printed out on optional printer

— SAVE RECALL OTHER options

— Job Sequencing

— Calibration Pulse (activation or deactivation).

11.

PRT

key which permits display of parameters and dynamic process

conditions when optional CRT monitor or printer is used. Green LED in
upper left corner indicates when data is being transmitted to a peripheral
accessory.

12.

MAN

key which is only used with rotary table operation to select normal

single cycle indexing (the default mode).

13.

AUTO

key which is only used with rotary table operation to select

continuous cycling.

14.

0-9 Numeric key pad

which allows input of numeric data or numeric

selection options by pressing the keys.

15.

ENTER

key which enters data into the system as keyed in with numerical

keys and displayed on the LCD screen.

16.

CE

key which cancels a prior parameter value when a new value is to be

entered. Red LED in upper left corner indicates key is functional and will
cancel a value displayed when depressed.

17.

O.L. RESET

key which resets the power supply following an overload

condition. Red LED in upper left corner indicates an overload condition
exists.