F U S E / C I R C U I T B R E A K E R

“ARRAY FUSE” - An array fuse is included for the 30 amp PPC. (Not available on 50 amp units

(Option P)). This will protect the controller from over-current from the solar panels or a short
circuit at the array. Replacement is a 30 amp AGC fuse.

“LOAD PROTECTOR” - A load circuit breaker is included with the PPC. This provides over-

current protection for the load circuit (PPC and load connections) and provides protection from
a short circuit at the load. This also can be used as an on/off switch for the load.

O P T I O N S

NOTE : Options cannot be added to units after production. Some of the features and functions
described in this manual are not included on all of the units.

OPTION M - OUTDOOR ENCLOSURE (NEMA 4X with Clear Door)

This enclosure is intended for use indoors or outdoors for watertight, dust tight and corrosion-

resistant applications and provides a clear door for viewing metering and status lights without
opening the enclosure.

OPTION P - 50 AMP CHARGE CURRENT

This option provides 50 amps of charging current capabilities. The terminal accept up to 6 AWG

wire. Load ratings remain as stated in the specifications.

Advertising