Ppc - 12 - p, Parameters units nominal voltages – Specialty Concepts PPC User Manual

Page 2

Advertising
background image

NOMINAL

MODEL

VOLTAGE

OPTIONS

PPC

12

M - Outdoor enclosure -

24

NEMA 4X

36

P - 50 Amp charge current

48

(12 or 24 volt units)

Specifications and product availability subject to change without notice.

PART NUMBERING KEY

EXAMPLE:

Model
Nominal Voltage
Options

PPC - 12 - P

PARAMETERS

UNITS

NOMINAL VOLTAGES

12 v

24 v

36 v

48 v

Charge Current, Continuous (1)

(Amps)

30

30

30

30

Charge Current, Max (60 seconds) (2)

(Amps)

39

39

39

39

Load Current, Continuous (3)

(Amps)

30

20

15

15

Load Current, Max (60 seconds) (4)

(Amps)

39

26

20

20

Array Voltage, Max Voc

(Volts)

22

44

66

88

Operating Voltage @ Battery, Minimum

(Volts)

8.5

17.0

25.5

34.0

Quiescent Current (5)

(Milliamps)

10

10

10

10

Current Consumption, Charging (6)

(Milliamps)

160

160

80

80

Current Consumption,

Load Disconnected (7)

(Milliamps)

140

100

70

70

Voltage Drop, Typ. (Array to Battery)

(Volts @ Max rating)

.15

.15

.15

.15

Voltage Drop, Typ. (Battery to Load)

(Volts @ Max rating)

.40

.40

.40

.40

Full Charge Termination (8)

(Volts)

14.8 + .2

29.6 + .4

44.4 + .6

59.2 + .8

Full Charge Resumption

(Volts)

12.8 + .2

25.6 + .4

38.4 + .6

51.2 + .8

Load Disconnect (9)

(Volts)

11.5 + . 2

23.0 + .4

34.5 + .6

46.0 + .8

Load Disconnect Adjustment Range

(Volts)

11.0 to 12.0

22.0 to 24.0

33.0 to 36.0

44.0 to 48.0

Load Reconnect

(Volts)

13.0 + .3

26.0 + .6

39.0 + .9

52.0 + 1.2

Float Voltage

(Volts)

14.1 + .2

28.2 + .4

NA

NA

Float Current, Max

(Amps)

3

1

NA

NA

Meter Accuracy, Voltage

5 %

5 %

5 %

5%

Meter Accuracy, Current

5 %

5 %

5 %

5%

Temp. Compensation coef.(from 25

°

C)

(Volts/

°

C)

-.03

-.06

-.09

-.12

Operating Temp. Range

(

°

C)

-20 to 50

-20 to 50

-20 to 50

-20 to 50

Storage Temp. Range

(

°

C)

-55 to 85

-55 to 85

-55 to 85

-55 to 85

Notes:
(1) 50 amp option available (avail. on 12, 24v units)
(2) With 50 amp option, value is 65 amps
(3) Non-inductive.
(4)

Carry only, Non-switching

(5) Both relays unenergized, red L.E.D.s off, typical value.
(6) Charge relay energized, red L.E.D. on, typical value.
(7) LVD relay energized, red L.E.D. on, typical value.
(8) Set-point adjustable. Refer to table.

Control SWITCH POSITIONS

Voltage

A

B

C

D

12

15.3

14.8

14.3

13.8

24

30.6

29.6

28.6

27.6

36

45.9

44.4

42.9

41.4

48

61.2

59.2

57.2

55.2

FULL CHARGE TERMINATION SET-POINTS

DIMENSIONS

In Inches (cm)

STANDARD ENCLOSURE (NEMA 13)

8.75

8.0

( 22.2 )

( 20.3 )

6.0 ( 15.2 )

8.0 ( 20.3 )

Depth: 4.5 Inch ( 11.4 cm)
Shipping weight: 10 lbs. (4.5 Kgs.)

S P E C I F I C A T I O N S