Installation of remote switch for rn/rp gas valve, Optional fan kit - fk24, Standard with rfs42 – Vermont Casting RFS32 User Manual

Page 6

Advertising
background image

- 6 -

INSTALLATION OF REMOTE

SWITCH FOR RN/RP GAS VALVE

Install on/off switch assembly on either the rear right or
left side of the RFS22/RFS32/RFS42 Gas Fireplace.
1.

Remove the screw at the back of the cabinet top either
on the left or the right side of the fireplace.

2.

Position switch assembly onto the back of the fireplace,
then fasten two screws as shown in Fig. 5.

3.

Attach wiring under the clips on the rear casing (Fig. 5)
and install wiring through the rear opening of the
fireplace before connecting to the valve as shown in
Fig. 4.

PILO

T

TPTH

TP

TH

ON/OFF SWITCH OR

MILLIVOLT THERMOSTAT

VALVE

THERMOPILE

Screw

(through existing hole)

Screw

On/off switch

assembly

Clips

Wiring for milli-volt

gas valves

Fig. 4

Fig. 5

A

B

C

BLACK
WHITE
GROUND

A = Speed Control
B = Temperature Sensor
C = Fan

OPTIONAL FAN KIT - FK24

It will be easier to install the fan before
connecting the gas line to the fireplace.

1.

Open front access door panel by pulling forward on
brass lip.

2.

Guide the fan through the opening at the back of the
pedestal, with the outlet pointed up and the fan mounting
bracket facing the back of the fireplace. The fan mounts
over two studs which hold the fan just below the firebox
floor. Do not install this fan on the base. Hold the fan
in place with the two nuts provided. (Fig. 7)

3.

Locate the fan speed control/junction box on screw
studs provided on base of the fireplace. Tighten with
3/8" nuts provided.

4.

Install thermal sensor element on screw studs located
to the right of the gas valve on the burner base.

5.

Plug in grounded service cord to a convenient wall
receptacle.

THIS FAN ASSEMBLY COMES COMPLETELY WIRED
TO ELIMINATE THE NEED FOR ELECTRICIANS. THIS
ELECTRICAL DEVICE, WHEN INSTALLED, MUST BE
ELECTRICALLY CONNECTED AND GROUNDED IN
ACCORDANCE WITH LOCAL CODES. IN THE ABSENCE
OF LOCAL CODES, WITH THE CURRENT CSA C22.1

CANADIAN ELECTRICAL CODE.

FOR U.S.A. INSTALLATION: FOLLOW LOCAL CODES
AND THE NATIONAL ELECTRICAL CODE ANSI/NFPA
NO.70-1984.

Fig. 6

Fig. 7

Should this fan require servicing, the power
supply must be disconnected. For rewiring of
any replacement components see Fig. 6.

TOP VIEW

Valve

Fan speed control/
Junction box

Thermal sensor
location

Fan is installed at the back
of the pedestal

Stud

STANDARD WITH RFS42

Fig. 3

it

HI

LO

OFF

PILOT

Thermostat

Bulb

Control

Knob

Minimum

Rate Screw

(Non-Adjustable)

Pilot Adjustment

Screw

Control

Knob

Pressure

Regulator

Brass Plug

Brass

Plug

Pilot Tube entry

Thermocouple

Inlet

Gas Inlet

Manifold Gas Outlet

On fireplaces equipped with Eurosit 630 gas valves there
are brass plugs in two of the holes. These plugs are not
to be removed

. The gas inlet hole has a plastic cap in it.

Remove the plastic cap and connect your gas supply line
at this point. (Fig. 3).

PILOT

ADJ

TH

TP

TP TH

Advertising