Switching characteristics – Cypress CY7C140 User Manual

Page 6

Advertising
background image

CY7C130, CY7C130A
CY7C131, CY7C131A

CY7C140, CY7C141

Document #: 38-06002 Rev. *E

Page 6 of 19

Switching Characteristics

Over the Operating Range

[7, 12]

Parameter

Description

7C131-15

[4]

7C131A-15

7C141-15

7C130-25

[4]

7C131-25
7C140-25
7C141-25

7C130-30

7C130A-30

7C131-30
7C140-30
7C141-30

Unit

Min

Max

Min

Max

Min

Max

Read Cycle

t

RC

Read Cycle Time

15

25

30

ns

t

AA

Address to Data Valid

[13]

15

25

30

ns

t

OHA

Data Hold from Address Change

0

0

0

ns

t

ACE

CE LOW to Data Valid

[13]

15

25

30

ns

t

DOE

OE LOW to Data Valid

[13]

10

15

20

ns

t

LZOE

OE LOW to Low Z

[10, 14, 15]

3

3

3

ns

t

HZOE

OE HIGH to High Z

[10, 14, 15]

10

15

15

ns

t

LZCE

CE LOW to Low Z

[10, 14, 15]

3

5

5

ns

t

HZCE

CE HIGH to High Z

[10, 14, 15]

10

15

15

ns

t

PU

CE LOW to Power Up

[10]

0

0

0

ns

t

PD

CE HIGH to Power Down

[10]

15

25

25

ns

Write Cycle

[16]

t

WC

Write Cycle Time

15

25

30

ns

t

SCE

CE LOW to Write End

12

20

25

ns

t

AW

Address Setup to Write End

12

20

25

ns

t

HA

Address Hold from Write End

2

2

2

ns

t

SA

Address Setup to Write Start

0

0

0

ns

t

PWE

R/W Pulse Width

12

15

25

ns

t

SD

Data Setup to Write End

10

15

15

ns

t

HD

Data Hold from Write End

0

0

0

ns

t

HZWE

R/W LOW to High Z

[15]

10

15

15

ns

t

LZWE

R/W HIGH to Low Z

[15]

0

0

0

ns

Shaded areas contain preliminary information.

Notes

12. Test conditions assume signal transition times of 5 ns or less, timing reference levels of 1.5V, input pulse levels of 0 to 3.0V and output loading of the specified

I

OL

/I

OH,

and 30 pF load capacitance.

13. AC Test Conditions use V

OH

= 1.6V and V

OL

= 1.4V.

14. At any given temperature and voltage condition for any given device, t

HZCE

is less than t

LZCE

and t

HZOE

is less than t

LZOE

.

15. t

LZCE

, t

LZWE

, t

HZOE

, t

LZOE

, t

HZCE

and t

HZWE

are tested with C

L

= 5 pF as in part (b) of AC Test Loads. Transition is measured ±500 mV from steady state voltage.

16. The internal write time of the memory is defined by the overlap of CS LOW and R/W LOW. Both signals must be low to initiate a write and either signal can

terminate a write by going high. The data input setup and hold timing should be referenced to the rising edge of the signal that terminates the write.

[+] Feedback

Advertising
This manual is related to the following products: