Switching characteristics – Cypress CY7C140 User Manual

Page 8

Advertising
background image

CY7C130, CY7C130A
CY7C131, CY7C131A

CY7C140, CY7C141

Document #: 38-06002 Rev. *E

Page 8 of 19

Switching Characteristics

Over the Operating Range

[7,12]

Parameter

Description

7C130-35
7C131-35
7C140-35
7C141-35

7C130-45
7C131-45
7C140-45
7C141-45

7C130-55
7C131-55
7C140-55
7C141-55

Unit

Min

Max

Min

Max

Min

Max

Read Cycle

t

RC

Read Cycle Time

35

45

55

ns

t

AA

Address to Data Valid

[13]

35

45

55

ns

t

OHA

Data Hold from Address Change

0

0

0

ns

t

ACE

CE LOW to Data Valid

[13]

35

45

55

ns

t

DOE

OE LOW to Data Valid

[13]

20

25

25

ns

t

LZOE

OE LOW to Low Z

[10, 14, 15]

3

3

3

ns

t

HZOE

OE HIGH to High Z

[10, 14, 15]

20

20

25

ns

t

LZCE

CE LOW to Low Z

[10, 14, 15]

5

5

5

ns

t

HZCE

CE HIGH to High Z

[10, 14, 15]

20

20

25

ns

t

PU

CE LOW to Power Up

[10]

0

0

0

ns

t

PD

CE HIGH to Power Down

[10]

35

35

35

ns

Write Cycle

[16]

t

WC

Write Cycle Time

35

45

55

ns

t

SCE

CE LOW to Write End

30

35

40

ns

t

AW

Address Setup to Write End

30

35

40

ns

t

HA

Address Hold from Write End

2

2

2

ns

t

SA

Address Setup to Write Start

0

0

0

ns

t

PWE

R/W Pulse Width

25

30

30

ns

t

SD

Data Setup to Write End

15

20

20

ns

t

HD

Data Hold from Write End

0

0

0

ns

t

HZWE

R/W LOW to High Z

[15]

20

20

25

ns

t

LZWE

R/W HIGH to Low Z

[15]

0

0

0

ns

Busy/Interrupt Timing

t

BLA

BUSY LOW from Address Match

20

25

30

ns

t

BHA

BUSY HIGH from Address Mismatch

[17]

20

25

30

ns

t

BLC

BUSY LOW from CE LOW

20

25

30

ns

t

BHC

BUSY HIGH from CE HIGH

[17]

20

25

30

ns

t

PS

Port Set Up for Priority

5

5

5

ns

t

WB

[18]

R/W LOW after BUSY LOW

0

0

0

ns

t

WH

R/W HIGH after BUSY HIGH

30

35

35

ns

t

BDD

BUSY HIGH to Valid Data

35

45

45

ns

t

DDD

Write Data Valid to Read Data Valid

Note 19

Note 19

Note 19

ns

t

WDD

Write Pulse to Data Delay

Note 19

Note 19

Note 19

ns

Interrupt Timing

t

WINS

R/W to INTERRUPT Set Time

25

35

45

ns

t

EINS

CE to INTERRUPT Set Time

25

35

45

ns

t

INS

Address to INTERRUPT Set Time

25

35

45

ns

t

OINR

OE to INTERRUPT Reset Time

[17]

25

35

45

ns

t

EINR

CE to INTERRUPT Reset Time

[17]

25

35

45

ns

t

INR

Address to INTERRUPT Reset Time

[17]

25

35

45

ns

[+] Feedback