Software controlled store and recall cycles, Switching waveforms – Cypress CY14B101Q3 User Manual

Page 17

Advertising
background image

PRELIMINARY

CY14B101Q1
CY14B101Q2
CY14B101Q3

Document #: 001-50091 Rev. *A

Page 17 of 22

Software Controlled STORE and RECALL Cycles

Parameter

Description

CY14B101Q1

Unit

Min

Max

t

RECALL

RECALL Duration

200

μs

t

SS

[12, 13]

Soft Sequence Processing Time

100

μs

Switching Waveforms

Figure 24. Software STORE Cycle

[12]

Figure 25. Software RECALL Cycle

[12]

0 0

1 1

1 1

0

0

CS

SCK

SI

RWI

Hi-Z

0 1 2 3

4 5

6 7

RDY

tSTORE

0 1

1 0

0 0

0

0

CS

SCK

SI

0 1

2 3

4 5

6 7

RWI

Hi-Z

RDY

tRECALL

Notes

12. This is the amount of time it takes to take action on a soft sequence command. Vcc power must remain HIGH to effectively register command.
13. Commands such as STORE and RECALL lock out IO until operation is complete which further increases this time. See the specific command.

[+] Feedback

Advertising
This manual is related to the following products: