TeeJet TASC-6100 User Manual
Page 65

6-5
98-05018
R2
TASC 6100
Emergency
CE & S
TANDARD
V
ERSION
3. Adjust the boom pressure using the INC./
DEC. switch on the control console. INC.
will open the flow control valve and DEC.
will close the valve.
4. Once the desired pressure is attained, turn all
boom sections OFF.
D. Drive to the area to be covered. When the vehicle
reaches the starting point of the desired swath, turn
on the appropriate boom switches and the sprayer
starts to spray. At this point, the operator is
enjoying some monitoring functions of the TASC,
but has no automatic control of the flow control
valve.
E. Monitor Speed. Adjust the ground speed to reach
the target speed desired.
F. The console cannot automatically adjust for
changes in boom widths. If booms are shut off,
pressure must be reset using the INC./DEC.
switch. Areas accumulate normally. Speed reads
correctly.
Mid-T
Mid-T
ech
ech
MID-TECH recommends this procedure as a
temporary, emergency procedure only. The prob-
lem should be resolved as soon as possible to allow
full automatic control of the sprayer to be reestab-
lished.