TeeJet 844-R Speed Compensated Application Control User Manual
Page 18

18
98-05047
R0
Once the correct value is been entered, press the
P
RO
key to validate this
value and advance to the next step.
It is best to repeat the automatic speed calibration process at least twice and
use the average of the speed calibration numbers.
If the auto calibration mode is been activated, no other functions are
possible until the console receives speed pulses for calibration. To
deactivate the auto calibration mode, press the
+
key until a number is
displayed.
To manually enter the radar calibration value, first press the Auto/Man key to
put the console into radar mode. When the control console is in the radar
mode, “RAD” is displayed in the lower left of the console display. Now use
the
+
or keys to adjust the value.