Cal 0, Fil 67.00 pls flo, 854 sprayer control – TeeJet 854 Sprayer Control User Manual
Page 30

www.teejet.com
25
854 Sprayer Control
Figure 4-28: Automatic Calibration
CAL
CAL
0
As the known volume is pumped, the console will
count the pulses.
• Once the volume has been pumped, turn the
pump (or flow) off to stop counting pulses.
Figure 4-29: Automatic Calibration (continued)
CAL
56
3856
• Press the PROGRAM key. The console will
ask what volume was pumped.
• Use the PLUS and MINUS keys to adjust
the value to match the volume pumped (in
gallons/liters).
Figure 4-30: Automatic Calibration (continued)
6AL 1000
• Press the PROGRAM key to return to
programming mode.
• The new flow meter calibration will be
displayed.
• Press the PROGRAM key to accept the
value and advance to the next step.
• Follow the same procedures to repeat the
calibration process.
Figure 4-31: Automatic Calibration (continued)
FIL
67.00
PLS
FLO