Regulation base, Backlight, Regulation base backlight – TeeJet LH 85 User Manual
Page 24

O
PERATION
O
PERATORS MANUAL FOR THE
LH
85
S
PRAY
C
ONTROLLER
3.6
LH
A
GRO
REGULATION BASE
This menu item might not appear depending on model/settings.
If the system is fitted with a pressure senor and a flowmeter it is possible to select
which sensor should be used for measuring flow (and thus for rate control).
The following options are available:
Symbol
Description
Flowmeter
Pressing this key selects flow based
regulation.
Pressure sensor
Pressing this key selects pressure based
regulation.
Auto
When this key is pressed the LH 85 Spray
controller selects which flow input to be
used based on the minimum flow setting for
the flowmeter.
BACKLIGHT
The contrast and backlight settings for the display can be adjusted during
operation. Please refer to "Contrast/Light" on page 4.24 in the SETTINGS section
of this manual for detailed information.