Fieldpilot, Priority valve follow this hose, Disconnect here hose from priority valve n m – TeeJet FieldPilot Install John Deere 4710 & 4720 User Manual
Page 14
Advertising

www.teejet.com
15
FieldPilot
®
John Deere 4720
Locate the priority valve on the left side of the machine. Follow the hose indicated in the photograph and
disconnect it from the valve block located in the middle underneath the machine. Connect this hose to one
side of the shuttle tee. Connect hose
(N)
to the 90° adapter on the top of the shuttle and route it to the open
port on the load sense jam valve and shuttle. Connect hose
(M)
to the other side of the shuttle and route it to
the LS port on the FieldPilot valve.
Figure 1-9: Install Load Sense Hoses (JD 4720)
priority Valve
Follow this Hose
disconnect
Here
Hose from
priority Valve
N
M