Edm function / fire wall – TruTrak EMS BU (8300-065) User Manual

Page 21

Advertising
background image

TruTrak Flight Systems

19

EMS Installation Manual

JUNE 2009

8300-065 Rev D

J3 Pin

EDM Function / Fire Wall

NOT NINE CYL
NN OPTION

1 - CHT 1 J Type

RED

2 - CHT 2 J Type

RED

3 - CHT 3 J Type

RED

4 - CHT 4 J Type

RED

5 - CHT 5 J Type

RED

6 - CHT 6 J Type

RED

7 NO CONNECTION

8 + EGT 1 K type

YELLOW

9 + EGT 2 K type

YELLOW

10 + EGT 3 K type

YELLOW

11 + EGT 4 K type

YELLOW

12 + EGT 5 K type

YELLOW

13 + EGT 6 K type

YELLOW

14 + CHT 1 J Type

WHITE

15 + CHT 2 J Type

WHITE

16 + CHT 3 J Type

WHITE

17 + CHT 4 J Type

WHITE

18 + CHT 5 J Type

WHITE

19 + CHT 6 J Type

WHITE

20 - EGT 1 K type

RED

21 - EGT 2 K type

RED

22 - EGT 3 K type

RED

23 - EGT 4 K type

RED

24 - EGT 5 K type

RED

25 - EGT 6 K type

RED

J2 Pin

EDM Function / Fire wall

Notes

1 Sensor

Ground

Sensor use only

2 TACH

3 Fuel

Flow

4 OAT

Thermister

5 Fuel

Pressure

6 OIL pressure Sensor (Resistive type)

Factory setup only

7 CHT 2 Thermister or Second OAT sensor (CARB TEMP)

8 Sensor 12 volt supply

Sensor use only

9 Sensor 12 volt supply

Sensor use only

10 Sensor 12 volt supply

Sensor use only

11 Sensor

Ground

Sensor use only

12 Sensor

Ground

Sensor use only

13 Sensor

Ground

Sensor use only

14 Sensor 5 volt supply

Sensor use only

15 Sensor 5 volt supply

Sensor use only

16 Current

Transducer

17 Not used at this time

18 Oil Temperature Thermister

19 CHT

1

Thermister

20 Oil

Pressure

21 Not used at this time

22 - EGT 1 RED K type / # Nine EGT

23 + EGT 1 YELLOW K type / # Nine EGT

24 - EGT 2 RED K type / # Nine CHT

25 + EGT 2 YELLOW K type / # Nine CHT

Advertising