TruTrak Vizion 380-385 Install manual User Manual

Page 15

Advertising
background image

TruTrak Flight Systems

13 Vizion 380/385 Series Autopilot Installation Manual

December 2013

8300-086 Rev IR

KMD 150

Power the KMD 150 up and turn it full bright. Press the MENU button then the SETUP button then the INST & DIAGS

button then the DATA IN/OUT. Change the DATA OUT PUT to NEMA 0183 the manual states the Baud rate is 9600. The
output pin is pin 11 and connects to the Primary Serial input on the auto pilot controller.
You will need to match 9600 Baud rate in the auto pilot.

KMD 150 connections to TruTrak autopilot

37 Pin Connector

on KMD 150

Signal Name

Signal Name

(TruTrak)

P101 on

TruTrak Vizion

11

(AV NAV)

Primary Serial Input

17

Garmin GTN-650

Garmin GTN-650 connections to TruTrak autopilot

P1001

Signal Name

(Garmin)

Signal Name

(TruTrak)

P101 on

TruTrak Vizion

8

GPS RS 232 OUT 1

Primary Serial Input

17

10

GPS ARINC 429 OUT A

ARINC-A

14

29

GPS ARINC 429 OUT B

ARINC-B

15

Press and hold the HOME key when powering up the GTN-650. Release the key when the display activates. When the

config mode screen shows, touch GTN Setup.

Touch RS232. On channel 1 output, select Aviation. Back out to the main config menu.

Touch ARINC-429. On channel 1 output, select GAMA 1, Speed LOW. Back out to the main config menu.

Touch Update Config Module.

Make sure the autopilot baud rate is set to 9600.


Garmin 695/696/795/796

Garmin 696 connections to TruTrak autopilot

Garmin

Power/Data Cable

Signal Name

(Garmin)

Signal Name

(TruTrak)

P101 on

TruTrak Vizion

Blue Wire

GPS RS 232 OUT 1

Primary Serial Input

17

Select Tools -> Setup -> Interface


Select the drop down menu under Serial Data Format. Choose one of the formats that outputs NMEA Out. There are
three options:


-Aviation In/NMEA & VHF Out is 9600 baud
-GTX TIS-A In/NMEA & VHF Out is 9600 baud

-NMEA Out is 4800 baud

Be sure to match the autopilot baud rate setting to the correct one.

Advertising