Carrier Thermostat User Manual

Page 9

Advertising
background image

Fig. 11—Two-Speed Heat Pump

with Single-Stage Furnace

—Model 2S Thermostat

A98494

COOL/HEAT

STAGE 1

RVS COOLING

HEAT STAGE 3

COOL/HEAT

STAGE 2

FAN

24 VAC HOT

R

W/W1

Y/Y2

O/W2

Y1/W2

G

24 VAC COMM

N/A

OUTDOOR

SENSOR

CONNECTION

C

B

S1

S2

C

Y

Y2

C

W2

MODEL 2S

THERMOSTAT

SINGLE-STAGE

FURNACE

TWO-SPEED

HEAT PUMP

See notes 3, 9, and 11

R

Y1

O

R

W3

G

W

SUGGESTED DIP

SWITCH SETTINGS

ON

A

B

C

D

OFF OFF OFF OFF

Fig. 9—Two-Speed Air Conditioner

with 2-Stage or Variable-Speed Furnace

—Model 2S Thermostat

A98492

COOL STAGE 1

FAN

HEAT STAGE 1

COOL STAGE 2

HEAT STAGE 2

24 VAC HOT

R

W/W1

Y/Y2

O/W2

Y1/W2

G

24 VAC COMM

N/A

OUTDOOR

SENSOR

CONNECTION

C

B

S1

S2

C

Y2

C

MODEL 2S

THERMOSTAT

TWO-STAGE OR

VARIABLE-SPEED

FURNACE

TWO-SPEED

AIR CONDITIONER

See notes 2, 5, and 7

R

Y1

R

G

W/W1

HUM

Y/Y2

W2

Y1 *

SUGGESTED DIP

SWITCH SETTINGS

ON

A

B

C

D

OFF OFF ON OFF

Fig. 12—Two-Speed Heat Pump

with 2-Stage or Variable-Speed Furnace

—Model 2S Thermostat

A98495

COOL/HEAT

STAGE 1

RVS COOLING

HEAT STAGE 3

COOL/HEAT

STAGE 2

FAN

24 VAC HOT

R

W/W1

Y/Y2

O/W2

Y1/W2

G

24 VAC COMM

N/A

OUTDOOR

SENSOR

CONNECTION

C

B

S1

S2

C

Y2

C

W2

MODEL 2S

THERMOSTAT

TWO-STAGE OR

VARIABLE-SPEED

FURNACE

TWO-SPEED

HEAT PUMP

See notes 3, 6, 7, 9, and 11

R

Y1

O

O

R

W3

G

W/W1

Y/Y2

W2

HUM

Y1 *

*

SUGGESTED DIP

SWITCH SETTINGS

ON

A

B

C

D

OFF OFF OFF OFF

Fig. 10—Two-Speed Air Conditioner

with Typical Fan Coil—Model 2S Thermostat

A98493

24 VAC HOT

FAN

HEAT STAGE 1

COOL STAGE 2

HEAT STAGE 2

COOL STAGE 1

R

G

W/W1

Y/Y2

O/W2

Y1/W2

R

G

24 VAC COMM

N/A

OUTDOOR

SENSOR

CONNECTION

C

B

S1

S2

C

Y2

C

MODEL 2S

THERMOSTAT

TYPICAL

FAN COIL

TWO-SPEED

AIR CONDITIONER

See notes 2, 7, and 8

W2

Y

*

E

R

W3

Y1

SUGGESTED DIP

SWITCH SETTINGS

ON

A

B

C

D

OFF OFF ON OFF

9

Advertising