Safety information!

General information

Read and comply with this manual before installing or operating the equip-

ment.

Do not use the equipment if it is damaged.

Remove all packing material, remove the product from its packing-box, remove the

protective covers and keep, inspect the equipment.

If the equipment is damaged, notify the supplier and the carrier in writing within three

days; state the item number of the product together with the order number and the

supplier’s invoice number. Retain all packing material for inspection.

If the equipment is not used immediately, replace the protective covers. Store the

equipment in suitable conditions.

Intended use

The device is designed for

ambient and gas temperatures at the pressure trans-

ducer connection of +10°C to +40°C at continuous operation, up to +80°C for

short periods (< 5 minutes) at the pressure transducer. If installing the device into

a cabinet or a housing check maximum temperature. Ensure that the maximum

permitted gas temperature at the pressure transducer (see ”Technical data”) is

not exceeded.

Use the equipment and all system parts for the intended use only, i.e. for measure-

ment of vacuum in vessels designed for that purpose.

Connecting the device

Avoid uncontrolled overpressure (e. g. when connecting to a locked or blocked

tubing system).

Risk of bursting.

Comply with

max. permitted ambient and gas temperature (see ”Technical

data”) and make sure ventilation is adequate if the equipment is installed in a

housing or if ambient temperature is elevated.

Power supply by an internal 9V battery.

Do not charge the battery. Do not open the battery. Do not throw the battery into

fire. Do not heat over 100°C and do not bring in contact with water.

• Comply with maximum permissible pressures at the pressure transducer. See

section ”Technical data”.

• Connect hoses gas tight at the pressure transducer connection.

• Ensure the stability of hose connections.

• In case of residues or aggressive or condensable media install a gas washing

bottle if necessary.

Avoid high heat supply (e.g., due to hot process gases).

Connect the vacuum gauge to the vacuum application.

Position the vacuum gauge and its vacuum line in such a way that condensate can-

not flow towards the internal pressure transducer.