Safety information, General information, Intended use – VACUUBRAND DVR 3 User Manual

Page 4: Connecting the device, Notice

Advertising
background image

Documents are only to be used and distributed completely and unchanged. It is strictly the users´ responsibility to check carefully

the validity of this document with respect to his product. Manual: 999072 / 12/01/2011

page 4 of 18

General information

Read and comply with this manual before installing or operating the equip-

ment.

Remove all packing material, remove the product from its packing-box, remove the

protective covers and keep, inspect the equipment.

If the equipment is damaged, notify the supplier and the carrier in writing within three

days; state the item number of the product together with the order number and the

supplier’s invoice number. Retain all packing material for inspection.

Do not use the equipment if it is damaged.

If the equipment is not used immediately, replace the protective covers. Store the

equipment in suitable conditions.

Intended use

• The devices DVR 3 are electronic rough vacuum gauges of the facility perfor-

mance group II for the intended use in hazardous areas. They have a special

approval and are subject to the guideline 94/9/EG (see ”Declaration of Confor-

mity)”.

• Respect the permitted connection parameters.

Attention: DVR 3 has only an approval for zone 1 and zone 2.

• Electrical and vacuum components might require a separate approval (see also

”Accessories”).

• The device is designed for

ambient and gas temperatures at the pressure trans-

ducer connection of +10°C to +40°C at continuous operation, up to +80°C for

short periods (< 5 minutes) at the pressure transducer. If installing the device into

a cabinet or a housing check maximum temperature. Ensure that the maximum

permitted gas temperature at the pressure transducer (see ”Technical data”) is

not exceeded.

Use the equipment and all system parts for the intended use only, i.e. for measure-

ment of vacuum in vessels designed for that purpose.

Connecting the device

• Connect the vacuum gauge to the vacuum application.

• Position the vacuum gauge and its vacuum connection line so that condensate

cannot flow towards the internal pressure transducer.

Connect hoses at the pressure transducer connection gas tight.

• Ensure stability of the hose connection.

• Comply with all relevant

safety requirements.

Avoid uncontrolled overpressure (e. g. when connecting to a locked or blocked

tubing system).

Risk of bursting.

The power supply unit BVE 9V is an intrinsically safe electrical operating device

of the facility performance category 2 (PTB 98 ATEX 2206). The user can replace

the sealed power supply unit of vacuum gauges DVR 3 within the hazardous

area of category 2 (according to the approvals of power supply unit and vacuum

gauge). Further interventions and repair must only be done by the manufacturer.

Using non-genuine power supply units or doing further interventions void the ap-

proval for use in explosive areas.

• Power supply by an power supply unit BVE 9V. Do not charge the battery. Do not

open the battery. Do not throw the battery into fire. Do not heat over 100°C and

do not bring in contact with water.

NOTICE

NOTICE

Safety information!

Advertising