Locating stove continued, Minimum clearances to combustible surfaces – Vogelzang BX26E User Manual

Page 7

Advertising
background image

VGZ-006 / 20120225.0

BX26E-STD /

Page 7

Figure 3 – Top View

Minimum Corner Clearances from

Combustible Surfaces

LOCATING STOVE continued…

Figure 2 – Minimum Clearance Dimensions

from Combustible Surfaces

Figure 1 – Top View Minimum Clearance

Dimensions from Combustible Surfaces

WARNING: DO NOT USE SINGLE WALL CON-
NECTOR PIPE AS A CHIMNEY - A HOUSE FIRE
COULD RESULT.

MINIMUM CLEARANCES

TO COMBUSTIBLE SURFACES

Unit to Sidewall ......................................36 inches
Unit to Backwall .....................................36 inches
Unit Corner to Wall ................................36 inches
Pipe Connector to Backwall..................38 inches
Pipe Connector to Ceiling .....................18 inches

Failure to follow these minimum clear-
ance requirements may result in an unsafe
installation and could cause a fire.

8. This stove is NOT a UL listed stove.

CAUTION: KEEP FURNISHINGS AND OTHER
COMBUSTIBLE MATERIALS AWAY FROM THE
STOVE.

CAUTION: KEEP FURNISHINGS AND OTHER
COMBUSTIBLE MATERIALS AWAY FROM THE
STOVE.

COMBUSTIBLE
CONSTRUCTION
PER NFPA 211

FLOOR

PROTECTOR

DASHED LINE SHOWS

HORIZONTAL CHIMNEY

CONNECTOR AND

ADDITIONAL FLOOR

PROTECTION REQUIRED

BACKWALL

48"

36"

18"

18"

18"

38"

36"

70"

18"

SIDEWALL

COMBUSTIBLE
CONSTRUCTION
PER NFPA 211

36"

36"

CORNER CLEARANCES