INSTALLATION
1.Refer to the warning.
2.Install as close as possible to point where air is being used.
3.Install the unit with the air flowing through the body in the direction
indicated by arrow.
4.Install the same pipe-size unit as the pipeline in use. Avoid using
fittings, couplings, etc., that restrict air flow.
5.Do not install this unit on any application where the pressure drop
will exceed 20 psi. Downstream from a quick-opening valve, for example,
could cause a momentary drop in excess of 20 psi (1,4 bar).
6.Maximum inlet pressure and operating temperature ratings are:
transparent plastic bowls, 150 psig (10 bar) and 125 °F (52°C);
metal bowls, 250 psig (17 bar) and 175°F (79°C).
MAINTENANCE
1. EACH TIME THE BOWL IS CLEANED OR THE FILTER ELEMENT
REPLACED
A. Depressurize unit.
B. Inspect and replace crazed, cracked, damaged or deteriorated
seals and bowls with original manufacturer's approved seals only.
C. Inspect bowl and replace crazed, damaged or deteriorated bowl with a
new bowl.
2. Remove element and clean periodically by tapping on a hard surface,
and blowing off with a blow gun.
3. IF UNIT IS EQUIPPED WITH A MANUAL DRAIN, drain sump whenever
water can be seen in bowl by pushing up on the valve stem.
4. Before placing the unit in service, make sure that the bowl and bowl
guard are securely locked in place.
REPAIR KITS AND REPLACEMENT PARTS
O-Ring Kit .............................................................................GRP-95-264
Filter Element Kit ..................................................................FRP-95-235
Baffle Kit ...............................................................................FRP-95-069
Automatic Piston Drain .........................................................GRP-95-584
Plastic Bowl with check valve ...............................................GRP-96-310
Plastic Bowl ..........................................................................GRP-95-856
Metal Bowl with check valve .................................................GRP-96-506
Check Valve (for units w/o automatic
piston drain)..........................................................................GRP-96-102
Metal Bowl Guard .................................................................GRP-96-309
ACCESSORIES
Wall Mounting Bracket..........................................................GRP-95-754
Pipe Mounting Bracket .........................................................GRP-95-734