Service kits available – Wilkerson 2F300E User Manual
Page 2
Bowl Seal
Snap Fit Tab
Detent must snap
in groove for proper
assembly.
(To remove bowl
depress tab, turn
& pull bowl down. )
Bowl rotated 90
for illustration purposes
Filter Body
Element
Baffle
Torque:
.4 to .6Nm
(3 to 5 in. lb.)
Twist Drain
Torque: 1.1 - 1.7Nm
(10 - 15 in. lb.)
Deflector
Stem
Bowl
Differential
Pressure
Indicator (DPI)
Optional
Coalescing Unit Shown
1
2
3
4
5
Auto Drain
7
6
Particulate, Adsorber & Coalescing Filter
2F300E
OIL
Torque value for assembling
units together, port blocks,
and mounting brackets:
5 to 6 Nm (48 to 52 in.lb.)
M8 x 90 Bolt
(4 Places)
Note: If both mating faces have
an o-ring groove, units may need
to be assembled with two seals.
( One square and one round seal.)
M8 x 15 Bolt
(4 Places)
M8 x 20 Bolt
(4 Places)
Lightly grease with provided lubricant.
Inspect for nicks, scratches, and surface
imperfections. If present, reduced service life
is probable and future replacement should
be planned.
Clean with lint-free cloth.
Description
Kit Number
Contains Items
Element Kits -
(5) Bowl Seal and
(2) Element
5 Micron
P3NKA00ESE
40 Micron
P3NKA00ESG
Adsorber
P3NKA00ESA
25 Micron Porous Bronze
P3NKA00ESJ
Coalescing / Element
Grade 6
P3NKA00ESC
Coalescing / Element
Grade 10
P3NKA00ES9
DPI Repair Kit
PS781
(6) DPI components
(not all shown)
Auto Drain Kit
PS506
(7) Auto Drain
Assembly
Service Kits Available
The most effective method of testing whether an element needs
to be replaced is to smell the air coming from the adsorber.
Offensive odors will be present well before oil levels become
detectable.
4. For Coalescing filter, a 5 micrometer pre-filter is recommended
to protect the high efficiency filter and to prolong the elements
life.
5. The differential pressure indicator, located on top of the filter
body, gives a visual indication of the pressure differential
across the filter element. Change the filter element when half
or more of the orange piston is above the retaining ring when
air is flowing. For units without a differential pressure indicator,
pressure differential gauges should be used to determine when
the maximum recommended pressure differential has been
reached.
6. Shut off air supply and depressurize the unit, before servicing.
7. After servicing, apply system pressure and check for air leaks. If
leakage occurs, Do Not Operate — conduct servicing again.