Wilkerson M45 User Manual

Page 2

Advertising
background image

greater than 50 psid (3,4 bar). To avoid high surges which can either
ruin the element or momentarily allow downstream contamination,
use a slow-opening type valve.

MAINTENANCE

1. The element operates effectively when it is saturated. The element’s

useful life will end only when the Differential Pressure Indicator is
completely red. The element cannot be cleaned or reused and must
be replaced at the end of its useful life.

2. IF THE UNIT HAS A MANUAL DRAIN, DRAIN THE UNIT ONCE

EVERY 8 HOURS MINIMUM. If the unit is equipped with an automatic
drain clean the screen around the drain. Clean screen by blowing off
with air gun.

3. When bowl becomes dirty, replace the bowl or clean by wiping with a

clean, dry cloth.

4. Before placing the unit in service, make sure that the bowl is securely

bolted in place per noted torque specification.

REPAIR KITS AND REPLACEMENT PARTS

Filter Element Kit (kit includes filter element, element o-ring, and retainer
o-ring).

Element Types

Type B1

(1 micron)

Type C

(0.01 micron)

Type D

(oil vapor, adsorption)

M43

MSP-95-876

MTP-95-562

MXP-95-565

M45

MSP-95-500

MTP-95-500

MXP-95-500

Drain Plate Kit:

Drain Plate 9/16 diameter,
(Use with internal automatic
mechanical float drain no. GRP-95-981 ...........................GRP-95-391
Drain Plate (1/2NPT) .......................................................GRP-95-393
Drain Plate (RC1/2) .........................................................GRP-95-395

Bowl O-ring Kit .....................................................................GRP-95-290
Differential Pressure Indicator (Standard) ........................... DP2-01-001
Differential Pressure Indicator Removal Cap Kit:

(for 300 psig appl.) ...........................................................GRP-95-022

Internal Drains:

Automatic Mechanical Drain:
(Fluorocarbon 1/8 NPT seals w/ stem) ............................GRP-95-981
Automatic Mechanical Drain:
(Fluorocarbon R1/8 seals w/ stem)..................................GRP-96-300
Manual Override for Auto Drain:
(GRP-95-981) NPT Body Threads...................................GRP-96-001
(GRP-96-300) BSPP-G Body Threads ............................GRP-96-101

External Drains:

External Automatic Mechanical Drain ............................... X01-04-000
External Automatic Mechanical Drain ...............................X02-04-F00
External Automatic Mechanical Drain ...............................XB3-04-000

AUTOMATIC ELECTRIC DRAIN VALVE

Model

Number Kit

Port

Size

Orifice

Size

Electrical

Operating

Pressure

Min.

Max.

X20-02-EE00 1/4" NPT 7/16"

115 VAC/1Ph/50-60Hz 2 psig 300 psig

X20-02-ED00 1/4" NPT 7/16" 230 VAC/1PH/50-60Hz 2 psig 300 psig
X20-02-EC00 1/4" NPT 7/16"

24 VDC

5 psig 300 psig

X20-04-EE00 1/2" NPT 7/16"

115 VAC/1Ph/50-60Hz 2 psig 300 psig

X20-04-ED00 1/2" NPT 7/16" 230 VAC/1PH/50-60Hz 2 psig 300 psig
X20-04-EC00 1/2" NPT 7/16"

24 VDC

5 psig 300 psig

Differential

Pressure

Indicator

Stud

Element

O-ring

O-ring

Cover

O-ring

Screw
(2 Required)

O-ring

Nut
(Torque 8 ± 1 FT.-LB.)

Coalescing

Element
B1,C or
Adsorption Element
D (0.1 vapor removal)

Metal

Bowl
(1 Required)

Screws
(8 Required)
(Torque 54 ± 2 FT.-LB.)

Screws

(6 Required)

Automatic

Mechanical

Drain (Optional)

O-ring

Drain Plate

Drain Plate

Screws

(Torque

16± 2 FT.-LB.)

(6 Required)

Nut (For Auto Drain)

Advertising
This manual is related to the following products: