Dc electrical schematic legend, Preventive maintenance – Winco RP25/B User Manual
Page 15

Page 13
2030-00
60706-226
PREVENTIVE MAINTENANCE
A. Daily Maintenance Checklist
** Oil level is between the “L” low mark and the “H” high
mark on the dipstick
** Fuel tank full of proper grade of diesel fuel
** Water and sediment drained from water separator
** Radiator fi lled with the proper coolant mixture
** Check air cleaner service indicator. Change the fi lter
element when the red indicator fl ag is at the raised posi-
tion
** Inspect for any fl uid leaks
** Look for any loose or damaged parts
** Check belts for cracks or frays
** Check trailer hitch and safety chains for fi tness
** Check tires for proper pressure
** Check battery for proper fl uid level
** Check the generator control panel for loose or dam-
aged parts
** Check the unit for general appearance and cleanliness
DC ELECTRICAL SCHEMATIC LEGEND