Check for Short Circuits — Use an ohmmeter to

check resista'nce between the outside frame of the
cell and the high-voltage contact. In each case, the
resistance should be infinite (open circuit).

CHECK TOP GUIDE ^ (2000 Cfm Models)

1. Remove top guide assembly from cabinet by

removing the single screw below junction box.
See Fig. 5.

2.

Using ohmmeter, check for shorts between

contact spring and ground. Resistance should
be infinite.

3. Examine insulators for cracks or heavy dirt

buildup. Clean if dirty; replace if cracked.

CHECK SURGE RESISTOR - See Step 7 under
Diagnostic Tests.

The function of the surge resistor is to protect

the power supply from instantaneous “spikes” of
high-voltage power that occur when the unit arcs.
This important component must be operating

satisfactorily to adequately protect the power
supply. Do not bypass.

CHECK LIGHT AND LIGHT CIRCUIT - See Step

9 under Diagnostic Tests.

1 — Ground Wire

2 — Patch Cord for 115-v

Supply Voltage

3 — High Voltage Wire

(7500-v DC)

4 — Voltmeter with 25-Kv

DC Probe

5 — High Voltage Lead from Meter
6 — Common or Ground Lead

from Meter

Fig. 18 — Test Circuit Between Power Door

and Cabinet