Fig. 4 — transition from smaller ducts – Carrier 31MC User Manual

Page 3

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Fig. 3 — Left- and Right-Hand Assemblies

-------L.

RETURN
AIR

DUCT

Fig. 4 — Transition from Smaller Ducts

6. When installing unit at bottom return opening

of an upflow furnace;

a.

Center furnace on air cleaner cabinet and

remove components from cabinet.

b.

Field-fabricated support not required on

Carrier furnaces.

c.

When the furnace is larger or smaller than

the air cleaner, baffle off any mismatch
between furnace and air cleaner with
baffles, included with unit. Additional
support, such as support legs, is recom­
mended when furnace overhangs the air
cleaner.

prevefit

» cormt

fr««»

atsl

7. If a filter flag is used to indicate a clogged

filter, install it downstream of cleaner, follow­
ing instructions furnished with the filter flag.

8. Seal all joints on downstream side of air

cleaner.

9. Slide prefilter and air cleaner cells into cabinet.

Units are shipped for right-hand installation.
To convert from a right- to a left-hand unit,
reverse the position of the prefilter and the air
cleaner cells in the cabinet as indicated in Fig.
3. Be sure the air flow arrows are pointing to

the direction of air flow thru unit, and the

ionizer wires in the cell are adjacent to the
prefilter. The 31MC220 high-efficiency me­
chanical filter does not have a prefilter or
electronic cell. Simply reverse position of filter
element to change from right- to left-hand. An
air flow direction arrow is stamped on the
filter element.

10. Remove junction box cover on 31 MM and MP

units only. Fig. 5, item 1, located below
receptacle, item 2, on top inside of cabinet.
Install strain relief in opening for 120-volt
input supply, Fig. 2, item 10, in top of

cabinet. Connect 120-volt supply pigtails in

junction box with wire nuts provided, and

connect ground wire to green pigtail provided.
Wire supply voltage from fan circuit of system
to have air cleaner operating only when unit
fan is running. See Fig. 6, 7, 8 and 9 for
typical furnace wiring diagrams. All wiring
must

comply

with

applicable

local and

national codes.

11. Replace power door. Turn fastener knob

clockwise

until

power

door

is

securely

fastened, thus ensuring good electrical contact
between power door and unit components.
Diverse installations are shown in Fig. 12.

12. Check over the installation for correct sheet

metal and electrical work.