L3
(IF

3-PH)

NEUTRAL
OR

GROUND

X-

THERMOSTAT

CONNECTIONS

NEUTRAL

OR
GROUND

Fig. 10 — Typical Fan-Coil Wiring with 208/230-v

Supply and Single-Speed Fan Motor

Fig. 11 — Typical Fan-Coil Wiring with 208/230-v

Supply and Multispeed Fan Motor

Fig. 12 — Installation of 31MC Mechanical or 31 MM or MP Electronic Air Cleaner

Installation of 31 MC Mechanical Air Filter

1. Remove the access door and slide out mechani­

cal filter.

2. Follow steps 2, 3, 4, 5, 6, 7 and 8 of

Installation Procedure in this booklet.

3. Slide mechanical filter into cabinet. Be sure

arrow on filter is pointing in the direction of air
flow. Secure access door to cabinet with
fastener knob.