TROUBLESHOOTING GUIDE (Oontinued)

PROBLEM

CAUSE

CORRECTION

Air teak from Safety Vialve Rjssibie defect in Safety Valve. Operate safely valve manualfy by pulling on ring. If

yàvQ still leaks, it should be replaced.

Knocking Noise

Defective Check Valve.

Remove and clean or replace.

Ciorripressor (6 rrot supply^
ing enough air to operate
accissortes.

Fhulonged excessive use of air.Decrease amount of air usage.

Compreeeor te not large enough
for air requirement.

Check the accessory air requirement, if it is higher

than tfw SCFM or pressure auppBed by your air
compressor, you a iarger compressa.

Restricted air Irstake fitter.

Ciaan or replace ai r intake filler, Do not operate the
air oomprassor In the paint spray area.

Hole in hose.

Check and repiace if required.

Cheok Valve restricted.

Remove and cleam or replace.

Air teaks.

Tighten fittings, {See Air Leaks Section of
T^ubteshootlng Guide.)

Motor Wilt Not Rirt

Motor overload protection switch
has tripped.

Ljit motor cool off and overload switch will auto
rtailcally reset.

Tank pressure exceeds pressure
switch “cut-in" pressure.

Motor will start automatlc^ly when tank pressure

dh)p8 below ’cut-in" pressure of pressure switch.

Wrong gauge wire or length of
extension cord.

Check for proper gauge wire and cord iertgth,

Check Valve stuck open.

Remove and clean or replace.

Loose etectrical connections.

Check wiring connection inside pressure swilch
and terminal box area.

Possible defective capacitor;

Rsturn to Sears Service Center for inspection or

replacement If necessary.

Paint spray on internal motor
parts.

Have Checked at Sears Service Center Do not

operate the compressor in the paint spray area,
See fiammabie vapor warning on page 3.

Possible deieciivs motor.

Have checked at a local Sears Service Center.

F u s e blown, circuit breaker

tripped.

1.; Check fuse box for blown fuse and replace if

necessary. Re-set circuit breaker. Do not use a

fuse or circuit breaker with higher rating than thai
sfbcifled tor your particular branch circuit

2, Check for proper fuse: only “Fusslron“ type T
fuses ere acceptable.

3, Check for low voltage conditions and/or proper
extension cord.

4, Disconnect the other oiectical appliances from

circuit or operate ths compessor on its own branch
cirouiL

Pressure release valve on pi«s-
sore switch has not unloaded
head pressure.

Bleed the Hne by pushing the iever on the pressure
switch to ths "Off" position; if the valvo does not

open, replace it

Hagylalot knob ~ confirtu-

ous air leak. Regulator wilt

not shut-off at air outlet

Dirty or damaged regulator inter­
ne! parts.

Clean Of replace

regulator, or

internal

parta