Having a problem, My remotes will not activate the door, My lights will not turn off when door is open – Sears 139.53930D User Manual

Page 33: My motor unit hums briefly

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

HAVING A PROBLEM?

1. My door will not close and the light bulbs blink on

my motor unit:

The safety reversing sensor must be

connected and aligned correctly before the garage door
opener will move In the down direction.

• Verify the safety sensors are properly installed,

aligned and free of any obstructions. Refer to

Installation Step 10: Install The Protector Systent.

Check diagnostic LED for flashes on the motor unit

then refer to the Diagnostic Chart on

the following

page.

2. My remotes will not activate the door:

• Reprogram remotes following the programming

instructions. Refer to Programming.

If remote will still not activate your door, check

diagnostic LED for flashes on motor unit then refer to

Diagnostic Chart on

the following page.

3.

My door reverses for no apparent reason:

Repeat

safety reverse test after adjustments to force or travel
limits. The need for occasional adjustment for the force
and limit settings is normal. Weather conditions in
particular can affect door travel.

• Manually check door for balance or any binding

problems.

• Refer to Adjustment Step 2, Adjust the Force.

4. My door reverses for no apparent reason after fully

closing and touching the floor:

Repeat safety reverse

test after adjustments to force or travel limits. The need
for occasional adjustment for the force and limit settings
is normal. Weather conditions in particular can affect
door travel.

• Refer to Adjustment Step 1, Adjust the UP and DOWN

Travel Limits.

Decrease down travel by turning down

limit adjustment screw clockwise.

5. My lights will not turn off when door is open:

• The garage door opener is equipped with a security

light feature. This feature activates the light on when

the safety sensor beam has been obstructed.

Sending Eye Safety Reversing
Sensor (Amber Indicator Light)

Receiving Eye Safety Reversing
Sensor (Green Indicator Light)

6. My motor unit hums briefly:

• First verify that the trolley is against the stop bolt.

• Release the door from the opener by pulling the

Emergency Release Rope.

• Manually bring the door to a closed position.

• Loosen the chain by adjusting the outer nuf 4 to 5

turns. This relieves the tension.

• Run the motor unit from the remote control or door

control. The trolley should travel towards the door and
stop. If the trolley re-engages with the door, pull the

Emergency Release Rope to disengage.

• Decrease the UP travel by turning the UP Travel

adjustment screw 2 full turns away from the arrow.

• Re-tighten the outer nut so the chain is a 1/4" (6 mm)

above the base of the rail. (When the door is

reconnected and closed, the chain will sag. This is
normal.)

• If the trolley does not move away from the bolt, repeat

the steps above.

33

Advertising