In.1 off te st in.4 on, In.2 on – Conair Hopper Temperature Controller UGD031 User Manual

Page 53

Advertising
background image

C o n t r o l F u n c t i o n D e s c r i p t i o n s

( c o n t i n u e d )

Te s t M o d e
S c r e e n s

SCREEN 43

SCREEN 44 *

SCREEN 45

SCREEN 47

F u n c t i o n

To access the test mode screens, press "+"
button when you are in the test screen
(screen 41). To get out of the test mode
screens at any time, press the Scroll and "-"
buttons at the same time.

This is the Test Mode screen. While in the
test mode, you can see the status of the
inputs and outputs and you can toggle the
outputs on or off by pressing the up and
down arrow keys on the control.

This screen shows the state of digital input 1.
If the input is open, "OFF" will be displayed.
If the input is closed, "ON" will be dis-
played. Digital input 1 on a heater is the
process high temperature switch. This
switch is closed during normal operation. It
opens when it detects a high temperature
inside the process heater tube.

This is the heat enable/disable screen. It
shows the state of digital input 2. If the
input is open, "OFF" will be displayed. If
the input is closed, "ON" will be displayed.

This is the differential pressure (flow switch)
screen. It shows the state of digital input 4.
If the input is open, "OFF" will be displayed.
If the input is closed, "ON" will be dis-
played.

(continued)

in.1

OFF

tE

St

in.4

ON

O p e r a t i o n l

4 - 1 7

4

Opera

tion

in.2

ON

* See the supplied electrical draw-

ings to associate instruments to
inputs.