ENGINE SPECIFICATIONS

Type of Engine

Q-55G........................................ GN-480
Q-70G........................................ GN-570

Cooling Method............................Air-cooled
Rated Horsepower

Q-55G........................................ 15 at 3600
Q-70G........................................ 18at3600rpm v

Displacement

Q-55G....................................... 480cc
Q-70G......................................570CC

Compression Ratio...................... 8.6 to 1
Cylinder Block.............................. Aluminum with cast

iron sleeve

Type of Governor.........................Mechanical, fixed

speed

Engine Governed Speed............ 2500 rpm

Air Cleaner............ .....................Paper element with

foam pre-cleaner

Starter.......................................... 12 volts DC electric
Ignition System.............................. Solid state with

flywheel magneto

Recommended Spark Plugs

Champion.................................. RC12YC

AC........................................ .....R45S

Pram Autolite............................65
Spark Plug Gap.......................... 0.030 inch (0.8mm)

_________ SPECIFICATIONS

FUEL REQUIREMENTS

The “Q“ series generator is equipped with a gasoline

fuel system as standard equipment. Specific installa­
tions may provide either a separate fuel tank for the
generator, of the generator may “share“ the vehicle
engine’s fuel tank.

NOTE: Some installations using a “shared“ fuel tank
may have a generator fuel pickup tube that is shorter

than the vehicle engine’s pickup tube. Such an arrange­
ment causes the generator engine to “run out of gas“
while adequate fuel in the vehicle remains in the tank.

To reduce lead and carbon deposits use high quality

UNLEADED gasoline with the generator. Leaded REG­
ULAR grade gasoline is an acceptable substitute.

NOTE:

Using

“Unleaded“

gasoline

contributes

to

longer engine valve life by reducing lead and carbon
deposits.

CAUTION: Generac does not recommend using any
gasoline containing alcohol (such as “gasohor). If

you use any gasoline containing alcohol, it must not
contain more than 10 percent ethanol and It must be

removed from the tank during storage. Do NOT use
any gasoline containing methanol. If you use gas­
oline with alcohol, Inspect more frequently for fuel

leaks and other abnormalities.

ENGINE OIL REQUIREMENTS

Use a high quality detergent oil classified "For Service
SF“ and with an oil viscosity rating of SAE 10W-30 oil.
Do not pour in any additives to the recommended oil.
Engine crankcase capacity is 1.5 U.S. quarts. See
MAINTENANCE section for oil level check and filling
procedures.

GENERATOR SPECIFICATIONS

SERIES

Q-55G

Q-70G I

Rotor RPM

3600

3600

Rotor Poles

2

2

Engine RPM

2500

2500

Rated Max. Continous AC Output*

5500 watts (5.5 kW)

7000 watts (7.0 kW)

Voltage*

120

120

Rated Max. Continuous Current*

45.8 AC ampst

58.3 AC ampsV

1 Phase

1

1

Frequency

60 Hertz

60 Hertz

Weight

215 pounds

222 pounds

Length

25 inches

25 inches

Width

18.5 inches

18.5 inches

Height

15.75 inches

15.75 inches 1

* All units are reconnectable to 120 and/or 240 volts, dual voltage output. Units are not listed per RVIA/ANSI when
reconnected for dual voltage output.

t

Rated maximum continuous current at 240 volts is 22.9 amps.

V Rated maximum continuous current at 240 volts is 29.1 amps.

- 7 7 -