ENGINE AIR CLEANER

Clean and re-oil the foam pre-cleaner every three

months or every 25 hours of operation; whichever oc­
curs first. Sen/ice the foam pre^eaner more frequentiy
if you operate the generator in extremely dusty or dirty
conditions (Figure 10):

Turn KNOB counterclockwise to loosen.

Remove COVER, FOAM PRE-CLEANER and
PAPER RLTER.

Remove foam pre-cleaner from cover.

Wash foam pre-cleaner in liquid detergent and
water.

Wrap foam pre-cleaner in a cloth and squeeze dry.

Saturate foam pre-cleaner in engine oil. Squeeze
to remove excess oil and to distribute oil.

Install foam pre-cleaner into cover, followed by

K

filter. Tabs at edges of paper filter must lock

ots on cover.

• Insert bottom locking tag of cover into slot. Install

cover, foam pre-cleaner and paper filter.

Once each year or every 100 operating hours (which­
ever comes first), replace the paper filter. The new
replacement filter must be a flame retardent type.

Figure 11

Areas to Clean on Air Intake Screen

ENGINE SPARK PLUGS

Clean engine spark plugs and reset gap to 0.030 inch
(0.8mm) every 100 hours of operation (Figure 12).
Clean by scraping or wire brushing and washing with
commercial solvent DO NOT BLAST CLEAN SPARK

PLUGS.

CAUTION: Sparking can occur If wire terminals do
not fit firmly over spark plug terminal ends. If nec­
essary, reform wire terminals to obtain a tight fit.

030" (.76 mm)

FEELER GAUGE'

Figure 10

Engine Air Cleaner

CLEAN AIR INTAKE SCREEN

Clean all foreign material from the air intake screen

(Rgure 11) at least once every 100 hours of operation.
Clean more often, if necessary.

Inspect the area around the generator exhaust muffler
periodically and remove all grass, leaves, dirt, etc. from

this area.

Figure 12

Setting Spark Plug Gap

FUEL FILTER

Remove and replace fuel filter (Rgure 13) every 100
hours of operation or once each year, whichever comes

first.

■ 1 3 -