3. Fill reservoir tank on log splitter. Remove the

the breather plug from breather tube. See figure

7. Pour approximately 3 gallons of Dexron
automatic transmission fluid ONLY into breather

tube.

A

CAUTION

DO NOT operate log splitter without
proper amount of oil in reservoir tank
(beam).

DEXRON

TRANSMI
FLUID

FUNNEL

BREATHER

TUBE- “

FIGURE?

TO START ENGINE

1.

Place throttle control lever (on beam) in run

position.

2. Move choke lever to CHOKE position.

3. Open the breather valve. Valve must be open when

running log splitter. Valve must be closed when
transporting log splitter. See figure 8.

4. Grasp starter handle, place one foot on wheel and

pull starter handle with a quick, full arm stroke.

Return rope slowly to the engine.

VALVE IN OPEN

VALVE IN CLOSED

POSITION

POSITION

1

• U- ■

BREATHER PLUG AND VALVE.

NOTE: Valve has left hand threads.

Clockwise to close.

TO STOP ENGINE

1. Move throttle control lever to STOP position.

2.

Remove high tension wire from spark plug to

prevent accidental starting by children while

equipment is unattended.

USING YOUR LOG SPLITTER

Your log splitter is designed for safe, efficient
operation. CARE, OF COURSE, MUST BE EXER­
CISED THAT HANDS ARE KEPT AWAY FROM
MOVING PARTS.

Engagement handle has three positions: (See figure 9)

Forward-Ram moves toward wedge.
Neutral—ram stops in place.

Reverse—ram returns.

ENGAGEMENT HANDLE

IN NEUTRAL POSITION.

ENGAGEMENT HANDLE
HELD IN FORWARD

POSITION.

ENGAGEMENT HANDLE
LOCKED IN REVERSE
POSITION.

STROKE RETURN STOP

PLUNGER.

FIGURE 8