6500XL Extended Life Generator

• The generator produces a very powerful voltage that can

cause serious injury or death by electrocution. Never

touch bare wires or receptacles. Never permit a child or
any unqualified person to operate the generator.

• Never handle any kind of electrical cord or device while

standing in water, while barefoot or while hands or feet
are wet Death or serious injury from electrocution may

result.

• Use a ground fault circuit interrupter (GFCI) in any damp

or highly conductive area (such as metal decking or steel
work).

• Never use worn, bare, frayed or otherwise damaged

electrical cords with the generator. Death, serious injury
and property damage from electrical shock may result

• Gasoline is highly FLAMMABLE and its vapors

EXPLOSIVE. Never allow smoking, open flames,

sparks or heat in the vicinity while h^dling

gasoline. Avoid spilling gasoline on a hot engine. Comply
with all laws regulating storage and handling of gasoline.

• Do Not overfill the fuel tank. Always allow room for fuel

expansion. If tank is overfilled, fuel can overflow

onto a hot engine and cause a FIRE or an

EXPLOSION.

Never store a generator with fuel in the tank where

gasoline vapors might reach an open flame, spark or pilot

light (as on a furnace, water heater, clothes dryer). FIRE

or an EXPLOSION may result.

• The unit requires an adequate flow of cooling air for its

continued proper operation. Never operate the unit

inside any room or enclosure where the free flow of
cooling air into and out of the unit might be obstructed.

Allow at least 2 feet of clearance on all sides of generator,

even while operating unit outdoors, or you could damage
the unit.

• Never start, or stop the unit with electrical loads

connected to receptacles with the connected devices

turned ON. Start the engine and let it stabilize before
connecting any electrical loads. Disconnect ail electrical

loads before shutting down the generator.

• Do Not insert any object through cooling slots of the

engine.You could damage the unit or injure yourself.

• Never operate the generator:

in rain; in any enclosed compartment: when connected

electrical devices overheat; if electrical output is lost; if

engine or generator sparks; if flame or smoke is observed

while unit is running; if unit vibrates excessively.

GROUNDING THE

G EN ER/VTOR

The National Electrical Code requires that the frame and
external electrically conductive parts of this generator be

properly connected to an approved earth ground. Local

electrical codes may also require proper grounding of the

unit. For that purpose, a GROUNDING WING NUT is
provided on the generator end (Figure I).

- Grounding Wing Nut

Generally, connecting a No. 12 AWG (American Wire

Gauge) stranded copper wire to the grounding wing nut

and to an earth—driven copper or brass grounding rod

(electrode) provides adequate protection against electrical

shock. Be careful to keep the grounding wire attached after

connecting the stranded copper wire. However, local codes

may vary widely. Consult with a local electrician for

grounding requirements in your area.

Properly grounding the generator helps prevent electrical

shock if a ground fault condition exists in the generator or

in connected electrical devices. Proper grounding also helps

dissipate static electricity, which often builds up in

ungrounded devices.