Operation – MTD Duerr 248-623-003 User Manual

Page 9

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

FIGURE 12

1.

Remove the four hex bolts and hex lock nuts

which are holding the two stripper halves
together.

2.

Slip one stripper half over the pipe flange on the
cylinder. Place the other stripper half on the
other side of the cylinder. See figure 12.

3.

Put two hex bolts through the top of the stripper

halves, and start hex nuts on the bolts. Start the

hex bolts and nuts through the bottom of the
stripper halves in the same manner.

4.

Make certain the cylinder is against the stops

located on the inside of the stripper halves.

Tighten all four nuts and bolts equally.

FINAL ASSEMBLY

1.

Make certain all nuts, bolts and hose clamps are

tightened securely.

2.

Before operating the log splitter, make certain to

follow the "Initial Preparation" instructions in the

Operation section.

ATTACHING THE STRIPPER ASSEMBLY

OPERATION

INITIAL PREPARATION

1.

On a firm, level surface, remove the spring pin

and clevis pin from the pivot latch. Place the

beam in the vertical position. Replace clevis pin
and spring pin in pivot latch for safekeeping.
Make certain the beam is straight up and down,
against the reservoir tank.

2.

Service engine with gasoline and oil as in­

structed in the separate engine manual packed
with your log splitter.

3.

Lubricate the beam area where beam will slide

with engine oil (DO NOT USE GREASE). Make
certain to oil both front and back of the beam
face. Pour some oil directly into the wedge
assembly.

4.

Fill the reservoir tank as follows.

a. Remove reservoir vent plug. See figure 13.

Using 10 Weight AW type fluid or Dexron II
automatic transmission fluid, fill reservoir

to the top. Replace vent plug securely.

b. Disconnect the spark plug wire and ground

against the engine. Prime the pump by
pulling the recoil starter, to turn the engine
over, approximately 10 times. Reconnect the
spark plug wire.

c. Start engine. Use the control handle to extend

the wedge to the far extended position. Leave
the wedge in this position (do not retract).

d. Refill tank to within 1-1/2" to 2" from the top

^ ^ of the tank. Total capacity of system is

approximately 6-1/2 gallons.

e. Now retract the wedge. Extend and retract

the wedge fully 10 to 12 complete cycles to

remove trapped air in the system (system is
"self-bleeding").

f. Refill the reservoir to within 1-1/2" to 2" from

the top of the tank. Much of the original fluid

has been drawn into the cylinder and hoses.
Make certain to refill the reservoir, to prevent
extreme damage to the hydraulic pump.
Failure to refill the tank will void your

warranty.

NOTE

Some fluid may overflow from the

vent plug as the system builds heat

and the fluid expands and seeks its
own level.

ik

WARNING

Do not operate the log splitter without

the proper amount of transmission
fluid in the reservoir tank.

BEFORE STARTING
Before each use, check the following:

1. On a firm level surface, remove the spring pin

and clevis pin from the pivot latch. Place the
beam in the vertical position. Replace clevis pin
and spring pin in pivot latch for safekeeping.
Make certain the beam is straight up and down,
against the reservoir tank.