2. Connect the positive (+) test iead of the a d-c voitnieter
to Pin 2 of Choke Moduie CM. Connect negative (-) test
iead to a ciean frame ground.

3. Crank the engine. The voitmeter should indicate about
7-10 volts d-c with engine cranking.

Test Results:

A. Engine won’t crank: Go to Problem No. 1.

B. Engine cranks but no d-c voltage is indicated: Replace
Choke Module CM and recheck for proper voltage. If
voltage is good, STOP test.

C. Engine cranks and normal voltage is indicated: Con­

tinue test.

4. Gain access to Brushes and Slip Rings (Fig. 16).

5. Connect the positive lead of a d-c voltmeter to the
terminal of the positive (+) brush (RED lead connection).
Connect voltmeter test lead to a clean frame ground.

6. Crank engine. The voltmeter should indicate about
7-10 volts d-c with engine cranking.

Test Results:

A. Engine won’t crank: Go to Problem No. 1

B. Engine cranks and no d-c voltage indicated, but volt­
age was indicated in Item 3 of test: Repair or replace

Wire 4 between Choke Module CM and the positive (+)

brush.

C. Engine cranks and normal voltage indicated: Go to
Step 7.

Step 7 - Check Stator Excitation Windings

Test Procedure: Disconnect Stator Excitation Winding
output leads 2 and 6 (Fig. 17) from the Electronic Voltage

Regulator. Set a VOM to its "Rxl" scale and zero the
meter. Connect VOM test leads across terminal ends of
Wires 2 and 6. The VOM needle should swing upscale
and Indicate the following resistance:

NP45G Units = 2.2 Ohms

NP55G Units = 1.8 ohms

NP65G Units = 1.6 ohms

*AII resistance values are plus or minus 10%.

Now, set the VOM to its "Rxl 0,000" scale and again zero

the meter. Connect one VOM test lead to Wire 2, and the

remaining test lead to a dean frame ground. You should
not detect any upscale movement (infinity) of the VOM
needle.

Test Results:

A. Excitation windings check GOOD: Go to Step 8. .

B. Excitation windings check BAD: Replace Stator As­
sembly.

NOTE: Also see INSULATION RESISTANCE TESTS
on Page 9. Typically, In the above test, a low resis­
tance indicates a shorted condition; a high resls-

tance Indicates an open condition._________________

Test 8 ■ Check Stator a-c Power Warnings

Test Procedure:, Test the Stator (Fig. 18) a-c power
windings as follows:

1. Disconnect a-c power winding output leads 11 and 22

from the Electronic Voltage Regulator.

2. Disconnect a-c power winding output lead 33 from
Circuit Breaker CB1.

3. At the wire nut junction of a-c output leads 22 and 44,
separate the two wires.

21