Automatic choke adjustment, Automatic choke adjustment c – Generac Power Systems IM Series User Manual

Page 27

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Automatic Choke Adjustment
C

Check automatic choke operation and (if necessary)

adjust the choke as foiiows:-

a. Check Choke Operation:- Crank the engine whiie ob­
serving automatic choke operation, initiaily, the Choke

Soienoid shouid energize to dose choke for about 0.2 to
0.4 seconds and then de-energize for about 2 seconds to
open the choke. This open/ciose cycie shouid repeat it-
seif untii the engine starts and cranking is terminated.

b. Pre-Choke Adjustment:- With engine cold and Choke
Solenoid NOT actuated, check that carburetor choke
plate is about 1/8 Inch away from its full open position. If
necessary to obtain the desired setting, use needle nose
pliers to bend tip of BI-METAL.

c. Choke Solenoid Adjustment:- Loosen screws that
retain the CHOKE SOLENOID to its retaining bracket.
Slide the CHOKE SOLENOID in the slotted holes to ad­

just axial movement of the SOLENOID plunger. Adjust
the axial movement so that, with the carburetor choke

plate closed, the CHOKE SOLENOID plunger Is just bot­

tomed in the solenoid coil (plunger at full actuated posi­
tion). With choke plate closed and plunger bottomed in

the coil, tighten the two screws. Then, crank engine and
check choke operation.

25

Advertising