High temperature shutdown, Field boost, Hour break in period – Generac Power Systems 00916-1 User Manual

Page 11: Duebunueoneid

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Generac NP-50G Recreational Vehicle Generator

Figure 5 — Switches fdi’ Engine

Safely Shutdown

HIGH TEMPERATURE
SWITCH

LOW OIL PI

■ HIGH TEMPERATURE SHUTDOWN

A high temperature switch (Figure 5) with normally-open (N.O.)
contacts is mounted near the oil filter. If engine temperature

were to exceed about 284°F (lAOX), the switch contacts

close and the engine shuts down.

■ FIELD BOOST_______________________________

The Controller Circuit Board houses a field boost diode and

resistor which are not part of the automatic choke circuit.

These two components are part of a “field boosf circuit (Rgure
6). During engine cranking oniy, a positive DC (battery) volt­

age is deiivered through the diode, resistor, brushes and slip
rings, and the generator rotor. Application of this voltage to

the rotor “flashes the field” whenever it is started. Fiashing of

the fieid each time the generator starts makes sure that a suf­

ficiently strong magnetic field is available to produce “pick-up”

voltage in the stator windings.

Figure 6 — Field Boost Circuit

CUISESI1Q
BUBIU

■ OVERVOLTAGE PROTEaiON________________

A solid state voltage regulator (Figure 7) controis the gener­

ator's AC output voitage. This regulator suppiies an excitation

current to the rotor. By regulating the rotor’s excitation cur­

rent, the strength of its magnetic fieid is reguiated and, in turn,

the voltage delivered to connected electrical loads is con-

trolied. When the AC frequency is 60 Hz, voltage is reguiated

at 120 volts (voltage-to-frequency ratio is 2-to-1).

Figure 7 — Solid State Voltage Regulator

I’

d

-»»»

TBum

10 MIMI __________

i==)^iH-^(inEn cnnam

—i-nmiiiifiii

ExanmoiiiinK

dUEBunueonEiD

The voltage regulator also incorporates a “voitage surge pro­

tection circuit.” This circuit prevents troublesome surges in the

generator AC output voltage. Voltage surge is a common cause

of damage to electronic equipment.

■ 25-HOUR BREAK IN PERIOD

The first 25 hours of operation is the break-in period for the
generator. Properly breaking in the generator is essential to

minimize fuel consumption and provide maximum engine per­
formance. During this 25-hour break in period, foiiow this

procedure:

• Run the unit at varying electrical loads, to help seat engine

piston rings properiy.

• Check engine oii levei frequently. Add oil if needed. It is

normal for the generator engine to consume more oil than
is normai until the piston rings have properly seated.

• For the 75-hour operation foilowing the break in period,

avoid light electrical loads. Load the generator at 50% (or
more) of its rated wattage capacity. Repeated iight loads
during these 75 hours can cause improper seating of engine
piston rings, resulting in blowby and high oii consumption.

• After operating the unit for 25 hours, complete the tasks rec­

ommended under “25-Hour Check Up."

R e c r e a t i o n a l V e h i c l e G e n e r a t o r

11