Generator control panel, Fuel primer, Start/stop switch – Generac Power Systems 00916-1 User Manual

Page 7: Fuse, Iviain breaker, Optional remote start/stop panel

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Generac NP-50G Recreational Vehicle Generator

GENERATOR CONTROL PANEL

Mounted on the generator control panel (Figure 2) are the fol­

lowing features:

Figure 2 — Generator Control Panel

MAIN

START ISA

---------------------- -------^

0

□ *

W

0

®

---------------------- ------

FUEL PRIMER

Before starting a coid engine (if it has not been started in more

than two weeks), you must press this switch for approximateiy

5 seconds to bring fuel from the tank to the carburetor. This

rocker type switch springs back into its originai position when

you reiease it.

START/STOP SWITCH

To crank and start the engine, hold this switch at its START

position. Release the switch when the engine starts. To stop

an operating engine, press and hoid the switch in its STOP

position untii the engine shuts off. The switch center position

is the RUN position.

FUSE

Protects the engine DC control circuit against eiectricai over-

ioad. If the fuse element has melted open due to overloading,

the engine cannot be cranked. If you must replace it, use oniy

an identicai replacement fuse.

IVIAIN BREAKER

Protects generators AC output circuit against overioad and pro­

vides a method of turning OFF the generators 120/240 volts

AC output to vehicle circuits. The NP-50G has one 20 amp

breaker and one 30 amp breaker.

NOTE:

If the Series NP-50G has been reconnected for dual

voltage AC output (120/240 volts), you can install line break­

ers having an amperage rating that is different than stated

above. The repiacement line breakers consist of two sepa­

rate breakers with a connecting piece between the breaker

handies (so that both breakers wiil operate at the same time).

If the unit is reconnected for dual voltage, it is no longer RVIA

listed.

OPTIONAL REMOTE

START/STOP PANEL

A remote mounted Start/Stop Panel is available, which aliows

you to start and stop the generator engine convenientiy from

inside the vehicie. Figure 3 shows the Model 9042 remote

panel which includes (a) start/stop switch and (b) a genera­

tor run lamp.

Figure 3 — Optional Remote Panel (Model 9042)

0

R.V.

You can also order model 9043, a remote panel which includes

the (a start/stop switch, (b) the generator run lamp and (c) and

hourmeter. The hourmeter provides a continuous indication

of engine-generator operating time. Use the hourmeter for

checking off periodic maintenance requirements on the unit.

R e c r e a t i o n a l V e h i c l e G e n e r a t o r

7