2. Mount Rotor.to Fan bosses. Use two

flat washers under each ,5/16-18 x 3/4

inch long capscrew - RAD.IUS. 0R_ CHAMF­

ERED SIDE OF WASHER,

must

: BE AGAINST

FLEK. C.OUELIN.G., Apply LOG-TITE 601 to

capscrew threads. Install capscrews

and torque to 19 Foot-Pounds.

STATOR

1. If previously removed, align

alternator adapter with stator can

and install. Slide alternator ada­

pter and stator can carefully over

the rotor, with stator bolt holes

in engine adapter and alternator

adapter aligned. Seat the mating

flanges of engine and alternator

adapter against each other.

REAR BEARING CARRIER

2. Slide a rubber vibration damp­

ener into place over slide pan

hole. Install bolt, with bolt head

at bottom of slide pan. Install

metal spacer, rubber washer, metal

washer, lockwasher and hex nut. Re­

peat for second vibration dampener.

Tighten both hex nuts.

1. Pull wire bundles through snap bushing in Rear Bearing Carrier. Then

align Carrier with rotor bearing and with threaded holes in engine ada­

pter. Lightly tap Carrier over rotor bearing.. Install four stator bolts»

with lockwashers. Grounding lug goes under upper left hand bolt, fuel

pump ground wire under lower left bolt. Retain fuel shutoff solenoid

clamp next to brush inspection window.