Starter motor, Check starter motor drive, Disassemble starter motor drive – Generac Power Systems TXP User Manual

Page 82: Check starter motordrive, Assemble starter motor drive

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

G E N E R A L

STARTER MOTOR

14

PLASTIC

CAP

PINION

pin

''

SPpViSa SPBINO

iNo C

ap

An exploded view of the starter is shown above. The starter uses a

gear type engagement, similar to an automobile. Energizing the starter

motor causes the helix on the starter to drive a pinion gear into eng­

agement with a ring gear. The pinion gear then cranks the engine.

C H E C K S T A R T E R M O T O R D R I V E

#

When the starter motor is energized, the pinion gear should move out

on its helix to engage the ring gear. If the motor drive does not re­

act properly, inspect helix-and pinion gear for freedom of movement.

If sticking or binding occur, the condition must be corrected. Pinion

must move freely on its helix. DO NOT LUBRICATE DRIVE ASSEMBLY.

D I S A S S E M B L E S T A R T E R M O T O R D R I V E

Clamp starter drive cap in a vise.

DO NOT CLAMP MOTOR SHELL IN VISE.

Use two screwdrivers to remove the

plastic cap, as shown. If cap be­

comes damaged, it must be replaced,

Use a 1/8 inch diameter punch and

a hammer to drive the roll pin out.

Rest retainer in a wood V-block, as

shown.

Issued 5-78

14.1

Advertising