F i g u r e 3 2 — G e n e r a t o r t o I n v e r t e r C o n n e c t i o n

f t f

GROUND FAULT CIRCUIT

INTERRUPTERS

The National Electric Code (NFPA 70, 551-7) requires
that you install ground fault circuit interrupters (GFCIs)
on all external and some internal electrical receptacles.
Contact your manufacturer or dealer for recommenda­
tions.

SENSING HARNESSES

Sensing harnesses have been provided with the generator
to connect to the inverter (Figure 32). The four (4)
DCpower wires (Red, Blue Black, and Green) may be cut
to the desired length to meet the installation (see Figure
32).

CAUTION: DO NOT in any way cut or shorten
the two sensing harnesses. If the harnesses
are too long, simply tie the excess up neatly
with standard cable ties.

— 29 —