25

TROUBLESHOOTING

Condition/Problem

Things to Check

Solution

Console will not power up/

turn on/start

Batteries

Make sure batteries are installed correctly. If batteries are

correctly installed, replace with a set of new batteries.

Check data cable integrity All wires in cable should be intact. If any are visibly crimped or

cut, replace cable.

Check data cable

connections/orientation

Make sure cable is connected securely and oriented properly.

Small latch on connector should line up and snap into place.

Check console display for

damage

Check for visual sign that console display is cracked or

otherwise damaged. Replace Console if damaged.
If the above steps do not resolve the problem, contact

Customer Care for further assistance.

Speed displayed is not

accurate

Display set to wrong unit

of measure. (English/

Metric)

Change display units (consult “Console Service Mode”)

Speed displayed is always

“0”/stuck in Pause mode

Data cable

Make sure the data cable is connected to the back of the

Console and the main frame assembly.

Speed Sensor (under

Shrouds)

Make sure the Speed Sensor Magnet and the Speed Sensor

are in place.

No speed/RPM reading

Check data cable integrity All wires in cable should be intact. If any are cut or crimped,

replace cable.

Check data cable

connections/orientation

Be sure cable is connected securely and oriented properly.

Small latch on connector should line up and snap into place.

Check Speed Sensor

Magnet position (requires

shroud removal)

Magnet should be in place on pulley.

Check Speed Sensor As-

sembly (requires shroud

removal)

Speed Sensor Assembly should be aligned with magnet and

connected to data cable. Realign sensor if necessary. Replace

if there is any damage to the sensor or the connecting wire.

Console displays “Lbatt”

error code

Batteries

Replace batteries

Unit operates but Tele-

metric Heart Rate not

displayed

Chest Strap (optional)

Strap should be “POLAR

®

” compatible and uncoded. Make

sure strap is directly against skin and contact area is wet.

Interference

Try moving unit away from sources of interference (TV, Micro-

wave, etc).

Replace Chest Strap

If interference is eliminated and HR does not function, replace

strap.

Replace Console

If HR still does not function, replace Console.

Console shuts off (enters

sleep mode) while in use

Check data cable integrity All wires in the cable should be intact. If any are cut or crimped,

replace cable.

Check data cable

connections/orientation

Be sure cable is connected securely and oriented properly.

Small latch on connector should line up and snap into

place.

Check Speed Sensor

Magnet position (requires

shroud removal)

Speed Sensor Magnet should be in place on pulley.

Check Speed Sensor As-

sembly

Contact Customer Care for further assistance.